If user wants to change
the length of the single arm of a clamping cylinder,
it should be noted that the length must be less
than 1.2 times the standard length in order to avoid
serious slanting of the piston rod. If the length
in design needs to be larger than the aforesaid
limit value, it is better to use double arms in
order to extend the life of the cylinder.
|
| » |
Workpiece should not
be clamped within the swing stroke during the downward
movement of the clamping arm, and should be clamped
within the vertical stroke only.
|
| » |
During the loading
and unloading of a workpiece, it is necessary to
use an air gun to clean the cylinder for removing
the iron slag or foreign objects attached thereon
in order to prevent the foreign objects from entering
the seal to cause oil / air leakage.
|
| » |
It is necessary to
use device having F.R.L. (Filters / Regulators /
Lubricators) function in the pneumatic line in order
to effectively remove the moisture, lubricate the
cylinder and avoid the damage of the swing mechanism
due to inertia impact of the clamping arm.
|
| » |
If the direction of
the single arm needs to be changed due to the problem
of piping, it should be done with a wrench by holding
the clamping arm first, and then unscrewing the
screw and knocking the clamping arm upward to change
its direction. One should not apply lateral force
to the clamping arm or laterally impact the clamping
arm to change its direction in assembled position.
This can cause damage of the swing mechanism due
to improper force applied on it.
|
| |
 |
| |
 |
| |
  |
  |
  |
| » |
R/L signifies right
hand swing / Left hand swing. Please indicate while
ordering. In right hand swing, when seen
from above while clamping down, the arm first swings
90 degrees* clockwise and then clamps down whereas
in left hand swing it rotates 90 degrees counterclockwise
and then clamps down.
|
| » |
*Clamps with swing
angle other than 90 degrees are also available.
Other swing angles available are 60° and 45°.
|
| » |
The power source should
not exceed the rated maximum pressure and the highest
flow value. |